L-Block Shield with Built-In Dose Calibrator

Compact L-Block shield with integrated dose calibrator shielding designed to maximize space and improve workflow in high-energy radionuclide preparation areas.
Key features and benefits
Integrated dose calibrator shield – eliminates the need for separate interlocking shielding rings
Compact L-Block design – maximizes workspace in hot labs with limited space
Built-in calibration chamber shield – provides shielding for through-mounted dose calibrator chambers
Designed for high-energy nuclides such as FDG F-18 – supports PET and high-activity workflows
Countertop through-mount configuration – allows chamber installation directly through the work surface (customer responsible for installation)
Compatible with Atomlab chambers and many others – accommodates multiple chamber types (verify fit per specifications)
Lead encased in steel construction – provides structural durability and shielding integrity
Clear viewing window – allows direct observation of the work area during dose preparation
Product overview
The L-Block Shield with Built-In Dose Calibrator is designed to support efficient dose preparation in facilities handling high-energy radionuclides such as FDG F-18. By integrating a calibration chamber shield directly into the L-Block structure, the unit maximizes usable workspace while reducing the need for separate shielding components.
The built-in shield is designed to accommodate a calibration chamber that is through-mounted in a countertop. This configuration supports direct access to the chamber during workflow. The shield accommodates all Atomlab chambers and many other models; however, chamber specifications should be verified to confirm proper fit. Installation of the through-mounted chamber is the responsibility of the customer.
Because the dose calibrator shielding is integrated into the L-Block, facilities do not need to purchase separate interlocking shielding rings. The unit is constructed of lead encased in steel to support durability and shielding performance in high-activity environments. This product should be specified as part of a broader radiation protection strategy and coordinated with surrounding shielding and workflow requirements.
When to use this product
Use this product when:
High-energy radionuclides such as FDG F-18 are prepared
Space limitations require compact shielding solutions
A dose calibrator must be integrated directly into the work surface
Separate interlocking shielding rings are not desired
PET workflows demand combined viewing and calibration shielding
Where this product is typically found
This unit is commonly used in:
PET hot labs
Nuclear medicine hot labs
Radiopharmacy preparation areas
Hospital nuclear medicine departments